SU420: [Impact: Critical] New FAS/AFF Drive firmware Support Bulletin Index

Views:
7,790
Last Updated:
2024/5/3 21:06:37

收藏

Summary

[Impact: Critical = Data loss/corruption, cluster data outage, or safety issue.]

NetApp® has identified various drive models as having higher failure rates with critical impact, and therefore recommends downloading and installing the latest drive firmware. The minimum drive firmware versions for the affected drive identification strings and part numbers are listed, below, with details in the referenced support bulletins.

Support Bulletin SU529: [Impact: Critical] SSD firmware for TPM5xxxATE/ATD to prevent potential data loss or disruption/unavailability

Part Number Drive Identifier Capacity Update to Minimum Drive FW
X/SP-357A X357_TPM5V3T8ATE 3.8TB NA55
X/SP-319A X319_TPM5V7T6ATE 7.68TB NA55
X/SP-371A X371_TPM5V960ATE 960GB NA55
X/SP-670A X670_TPM5V15TATE 15.3TB NA55
X/SP-379A X379_TPM5V960ATE 960GB NA55
X/SP-364A X364_TPM5V3T8ATE 3.8TB NA55
X/SP-374A X374_TPM5V960ATE 960GB NA55
X/SP-358A1 X358_TPM5V3T8ATE 3.84TB NA55
X/SP-386A1 X386_TPM5V960ATE 960GB NA55

1 FIPS (Federal Information Processing Standards - Encrypted)

Part Number Drive Identifier Capacity Update to Minimum Drive FW
X/SP-356A X356_TPM5V3T8ATE 3.8TB NA05
X/SP-447A X447_TPM5V800ATD 800GB NA05
X/SP-440A/B1 X440_TPM5V800ATD 800GB NA05
X/SP-363A X363_TPM5V3T8ATE 3.8TB NA05
X/SP-449A X449_TPM5V800ATD 800GB NA05
X/SP-577A1 X577_TPM5V800ATD 800GB NA05

1 FIPS (Federal Information Processing Standards - Encrypted)

Support Bulletin SU428: [Impact: Critical] HDD firmware for HCBFExxxA10 to prevent potential data loss or disruption/unavailability

Part Number Drive Identifier Capacity Update to Minimum Drive FW
X/SP-422A-R5 X422_HCBFE600A10 600GB NA06
X/SP-423A-R5 X423_HCBFE900A10 900GB NA06
X/SP-425A-R6 X425_HCBFE1T2A10 1.2TB NA06
X/SP-426A-R6 X426_HCBFE1T8A10 1.8TB NA06
X/SP-417A-R6 X417_HCBFE900A10 900GB NA06
X/SP-427B-R6 X427_HCBFE1T8A10 1.8TB NA06
X/SP-427A X427_HCBFE1T8A10 1.8TB NA06
X/SP-487A-R5 X487_HCBFE600A10 600GB NA06
X/SP-488A-R5 X488_HCBFE900A10 900GB NA06
X/SP-489A-R6 X489_HCBFE1T2A10 1.2TB NA06
X/SP-490A-R6 X490_HCBFE1T8A10 1.8TB NA06
X/SP-495A-R6 X495_HCBFE900A10 900GB NA06
X/SP-341A-R6 X341_HCBFE900A10 900GB NA06
X/SP-342A-R6 X342_HCBFE1T2A10 1.2TB NA06
X/SP-343A-R6 X343_HCBFE1T8A10 1.8TB NA06

Support Bulletin SU416: [Impact: Critical] HDD Firmware for Xxxx_SMEGxxxTxxx to prevent higher failure rate and potential data loss

Shelf Part Number Sysconfig - a Output Capacity Update to Minimum Drive FW
DS4246 X/SP-302A-R5 X302_SMEGA01TSSM 1TB NA01
X/SP-306A-R5 X306_SMEGA02TSSM 2TB NA01
X/SP-308A-R5 X308_SMEGA03TSSM 3TB NA01
X/SP-302A-R5 X302_SMEGA01TSSA 1TB NA02
X/SP-306A-R5 X306_SMEGA02TSSA 2TB NA02
X/SP-308A-R5 X308_SMEGA03TSSA 3TB NA02
X/SP-477A-R6 X477_SMEGX04TA07 4TB NA03
X/SP-309A-R6 X309_SMEGA03TA07 3TB NA02
X/SP-315A-R6 X315_SMEGA04TA07 4TB NA02
DS4486 X/SP-478A-R5 X478_SMEGA03TSDB 3TB NA01
X/SP-480A-R6 X480_SMEGA04TSDB 4TB NA01