SU542: Incorrect cluster interconnect cables bundled with FAS2820 orders
- Views:
- 347
- Last Updated:
- 1/27/2024, 12:17:33 AM
收藏
Summary
[Impact Medium]
10GbE cables were shipped instead of 25GbE cables for Cluster/HA ports of FAS2820 systems.
Issue Description
Incorrect cables (10Gb Ethernet Twinax cables instead of 25Gb Ethernet Twinax cables) for the Cluster/HA interconnect (switchless cluster) were included for some FAS2820 orders.
Impact: Workloads that consist of 100% remote sequential read operations might see a slight limit to their performance (throughput). Such a workload is unlikely.
Symptom
Using the "sysconfig -a 0"
nodeshell command, verify the link speed of ports e0a and e0b.
slot 0: Dual 10/25G Ethernet Controller E823L-SFP+
e0b MAC Address: d0:39:ea:ac:1a:91 (auto-10g_twinax-fd-up)
SFP Vendor: Molex Inc.
SFP Part Number: 747529663
SFP Serial Number: 305940049
e0a MAC Address: d0:39:ea:ac:1a:92 (auto-10g_twinax-fd-up)
SFP Vendor: Molex Inc.
SFP Part Number: 747529663
SFP Serial Number: 305940179
Device Type: E823L (0x124D)
Solution
- Open a support case to request correct cables and reference Support Bulletin SU542.
- Replacement cables will be sent the next business day, if possible for your location.
联想凌拓科技有限公司(“Lenovo NetApp”)不对本页面中提供的任何信息或建议的准确性、可靠性或可维护性,或通过使用这些信息或遵守本文中提供的建议可能获得的任何结果,提供任何陈述或保证。本页面中的信息是按原样分发的,使用这些信息或实施本文中的任何建议或技术是客户的责任,取决于客户评估这些信息并将其整合到客户的运营环境中的能力。本页面及其包含的信息只能与本页面中讨论的 NetApp 产品结合使用。在任何情况下,Lenovo NetApp 均不承担因与使用或执行本页面上提供的信息有关的或导致的任何特殊的、间接的或随之而来的任何损失,或者因使用、数据或利润损失(无论是否在合同履行中)、疏忽或其它侵权行为导致的任何损失。